{% block defect_grade_description %} {% set title = "Defect Grade Description / Inspection: Sewer ID: " ~ (inspection.header.pipe.pipeline_length_reference if inspection.header.pipe.pipeline_length_reference else "") %} {% set border_top = true %} {% include "wrc/mainline/page_title.html" %} {% include "wrc/mainline/table_header_row.html" %}
Brick: No Structural Defects
Pipe: No Structural Defects
Brick: Minor cracking, Surface mortar loss, Spalling slight, wear slight
Pipe: Circumfrential crack, Moderate joint defects, Spalling slight, Wear slight
Brick: Total mortorloss without other defects, single brick displaced, Deformation up to 5%, Spalling medium, Wear medium
Pipe: Fractures with deformation up tp 5%, Longitudinal cracking or mulitlpe cracking, Minor loss of level, More severe joint
Brick: Total mortorloss with deformation greater than 10%, Deformation up to 10% and fractured, Displaced/hanging brickwork, Small number of missing bricks
Pipe: Broken, Deformation up to 10% and broken, Fractured with deformation 5 - 10%, Multiple fractures, Serious loss of level, spalling large, wear large
Brick: Already Collapsed, Missing invert, Deformation over 10% and fractured, Displaced/hanging brickwork and deformation over 10%, Extensive missing bricks
Pipe: Already collapsed, Deformation over 10% and broken, Extensive areas of fabric missing, Fractured with deformation over 10%